X Ray Generator Packaging Size and Weight
Packaging Specification Parameters
32kW X Ray Generator
- Packaging Type: Carton packaging
- Outer Package Dimension: 725585cm
- Total Gross Weight: 100KG
50kW X Ray Generator
- Packaging Type: Plywood wooden case export packaging
- Outer Package Dimension: 1226086cm
- Total Gross Weight: 143.5KG
Packaging Advantages
-
Targeted Packaging Matching
32kW compact unit uses thickened shockproof carton with internal foam buffer, lightweight and cost-effective for small clinics and overseas small orders. The 50kW high-power generator is packed with fumigation-free plywood wooden case, which has strong compression resistance and impact resistance, effectively shielding precision circuit boards and transformers from vibration damage in long haul transport.
-
Standard Export Grade Material
All packaging materials comply with international export logistics standards. Wooden cases are fumigation-free, eliminating extra quarantine procedures at customs ports worldwide and speeding up import clearance for global medical device distributors. Shock absorption lining fills gaps inside packages to avoid component collision during handling, loading and unloading.
-
Optimized Size & Weight for Logistics
Packaging dimensions are designed to maximize container space utilization. Controlled gross weight helps customers cut international ocean freight and air freight costs. Clear size and weight data support accurate logistics quotation and cargo space booking in advance.
-
Complete Product Protection
Full wrapping film + internal shockproof foam + external rigid shell forms multi-layer protection, resisting moisture, collision, extrusion and dust during cross-border transportation. Each package can be labeled with customized shipping marks, product model and specification information as customer requirements.
Applicable Products
This packaging solution is exclusively designed for our full series medical high frequency X ray generators, including 32kW and 50kW models matched with DR digital radiography systems, compatible with dual column DR, U-arm DR and fixed X-ray radiography equipment for global hospitals, imaging centers and medical device integrators.Company AddressE Building, Future Star Innovation Industrial Zone, Weifang, Shandong, China
-
X Ray Generator 50KW NKG 50R 380AC
General Parameters
- Output power: 50kW
- Rated supply voltage: 380VAC ±10%, 50/60Hz ±1%; 220V single-phase optional
- Output frequency: 40kHz ±1%
- Tube voltage accuracy: ±3%
- Tube current accuracy: <±4% (ms>5); <±13% (ms≤5)
- Anode speed: 2800r/min
- Operating Keyboard: Full touch keyboard
- Parameter correction: One-click fully automatic parameter correction
Exposure Parameters
- Exposure mode: kV-mA-ms, kV-mAs, APR
- Tube voltage range: 40-150kV, 1kV step
- Tube current range: 10-640mA
- Exposure time range: 1-10000ms
- mAs range: 0.1-640mAs
- Exposure time accuracy: ≤±5%+0.2ms
- mAs accuracy: ≤±5%+0.2mAs
- APR storage capacity: 2400 data sets
- Auxiliary output power: 24VDC 300mA, 220VAC 5A
Optional Parameters
- AEC
- Density adjustment range: -3 ~ +3
- Power supply tolerance: -15V ~ +15V
- Communication interface: RS-232
- Function customization: Various interfaces can be customized according to customer requirements
Core Advantages of 50kW X-Ray Generator
Stable High-Frequency Output
40kHz high-frequency output ensures steady X-ray beam, effectively reducing image noise and improving the definition of subtle lesions such as tiny bone fractures and pulmonary nodules. Strict control over tube voltage and tube current accuracy eliminates imaging errors caused by unstable power supply.User Friendly Full Touch Control System
The integrated full touch operating keyboard supports three mainstream exposure control modes. The built-in APR function stores up to 2400 groups of pre-set exposure parameters for different body parts, greatly cutting down operation time for radiologists and improving daily examination throughput.Convenient Automatic Calibration
One-click fully automatic parameter correction function simplifies routine equipment maintenance. Technicians can complete accuracy calibration without complex manual adjustment, lowering equipment downtime and long-term maintenance costs for hospitals.Wide Adjustable Exposure Range
Wide adjustable tube voltage, tube current and exposure time ranges cover all common clinical radiography scenarios including pediatric radiography, limb fracture imaging, chest radiography and abdominal plain films. The flexible mAs setting range meets diverse diagnostic shooting demands.Flexible Customization & Optional AEC Function
Support optional AEC automatic exposure control to realize intelligent automatic exposure. RS-232 communication interface is standard, and other types of communication interfaces can be customized on demand to match different DR system integration solutions, compatible with dual column DR, U-arm DR and other digital radiography equipment.Multiple Power Supply Options
Dual power supply schemes of 380V three-phase and optional 220V single-phase adapt to power supply environments of clinics, community hospitals and large comprehensive hospitals worldwide. The independent auxiliary output power provides stable power support for peripheral detectors and control accessories.Application Scenarios
This 50kW high frequency X ray generator is widely matched with digital radiography DR systems for physical examination centers, general radiology departments, orthopedic clinics and medical imaging institutions, perfectly matching dual-column DR units and other fixed radiographic equipment. It provides accurate, clear and consistent X-ray imaging for routine chest radiographs, skeletal radiography and general diagnostic radiology work.E Building, Future Star Innovation Industrial Zone, Weifang, Shandong, China -
-
-
-
-
X-ray Radiation Protection Lead Clothes
X-ray Radiation Protection Lead Clothes are important protective equipment for individuals who may be exposed to harmful radiation in medical and industrial environments. These specialized aprons are designed to protect the wearer from the potential harmful effects of radiation, providing a high level of protection in environments that require attention to radiation.
-
Medical film printer for use with DR X-ray machine
Medical film printer, suitable for film output of medical images such as CT, MRI, DR, CR, digital gastrointestinal, DSA, breast, Nuclear medicine, digital mobile X-ray imaging, etc., adopts international mainstream imaging mode, direct thermal one-step imaging, and no exhaust gas is generated in the printing process, and no other consumables are required; It adopts the latest digital imaging principle and integrates four core technologies (Medical imaging receiving technology, digital image processing technology, temperature control technology and channel film sending technology), so that all kinds of Medical imaging can be restored on the film to the maximum extent and achieve efficient, environmentally friendly and accurate film printing.