NK-R102NC X-Ray Collimator

Short Description:

Newheek NK-R102NC X-ray collimator is a manual beam-limiting accessory designed for general diagnostic X-ray equipment with 150kV X-ray tubes. It precisely restricts the X-ray radiation field, reduces scatter radiation, cuts unnecessary radiation exposure and helps produce high-contrast radiographic images for medical diagnostic use.


  • FOB Price: US $0.5 - 9,999 / Piece
  • Min.Order Quantity: 100 Piece/Pieces
  • Supply Ability: 10000 Piece/Pieces per Month
  • Product Detail

    Product Tags

    Application

    The NK-R102NC collimator fits ordinary X-ray diagnostic equipment. It matches X-ray tubes with maximum operating voltage up to 150kV. It is widely used as a supporting component for stationary, mobile and portable X-ray machines in radiography rooms and bedside imaging scenarios.

    Key Technical Parameters

    • Matching X-ray tube maximum operating voltage: 150 kV
    • X-ray leakage: <0.5 mGy/h (150 kV, 4 mA)
    • Distance from X-ray tube focal spot to collimator mounting surface: 60 mm, adjustable for different tubes
    • Maximum field size: 45 cm × 45 cm (SID = 1 m)
    • Minimum field size: <3 cm × 3 cm (SID = 1 m)
    • Visible light field illuminance: >180 lux (SID = 1 m)
    • Contrast ratio: ≥4:1
    • Lead gate control method: Manual
    • Lamp on delay time (intermittent delay): 30 s
    • Light field alignment (single side): <1 % @ SID
    • Inherent filtration: 1 mm Al /75 kV
    • Power input: 24 VAC / 50 VA or DC 24 V / 2 A
    • Dimensions: 228 mm × 191 mm × 97 mm (L × W × H)
    • Weight: 5.5 kg

    Product Features

    This is a manual collimator with manually operated lead shutters. Operators can continuously adjust the opening size of lead gates to tailor the radiation field exactly to the region of interest. This limits X-ray beam coverage and lowers scatter radiation.

    It is equipped with LED light field simulation. The visible light field matches the actual X-ray beam, so technicians can preview the exposure area before activating X-rays. Light field illuminance is higher than 180lux at 1m SID, delivering bright, clear visualization. The 30-second lamp delay function protects the LED light source and extends service life.

    Light field alignment precision is within less than 1% on a single side, ensuring high consistency between light field and X-ray field. The focal distance from focal spot to mounting surface can be adjusted to adapt to different X-ray tube assemblies, bringing strong compatibility for different X-ray system integrators.

    Strict radiation leakage control is another highlight. Under 150kV,4mA working condition, leakage radiation stays below 0.5mGy/h, complying with international radiation safety requirements and protecting operators and patients.

    Working Principle & Practical Value

    The collimator uses movable lead shutters to block redundant X-rays outside the target imaging area. Narrowing the radiation field suppresses scattered radiation. Reduced scatter improves image contrast and diagnostic clarity, while minimizing radiation exposure to surrounding tissues.

    For X-ray system manufacturers and integrators, this collimator is a ready-to-install accessory. Its adjustable focal mounting distance supports integration into many custom-built 150kV diagnostic X-ray systems. It works well for hospital radiography, bedside mobile X-ray and general radiographic inspection.

    Summary

    Newheek NK-R102NC manual X-ray collimator is a reliable beam limiter for 150kV diagnostic X-ray machines. Featuring adjustable focal distance, high light field accuracy, low radiation leakage and simple manual control, it offers dependable beam shaping performance. It is a preferred radiology accessory for X-ray machine manufacturers and medical imaging system suppliers.